Obesity Raises Radiation Exposure During Epidural Procedures
By Ivan Urits, MD – Board Certified in Anesthesiology and Pain Medicine
Published July 1, 2025 | Category: Pain Medicine
Fluoroscopy-guided epidural injections expose patients and staff to radiation. Larger body size requires more X-ray energy to produce a clear image, and obesity is common among patients with chronic back pain. A 2025 analysis in Current Pain and Headache Reports examined how body weight, race and sex affect radiation exposure.
This summary is based on the published abstract. Read the abstract on PubMed
What the authors did
The authors performed a retrospective, case-controlled comparative evaluation of radiation exposure across epidural procedures in interventional pain practice, analyzing fluoroscopy time and dose by body mass index (BMI), race and sex.
What they found
- Obesity (BMI of 30 or more) affected 50.9% of patients, and was more common in those under 45, women and African American patients.
- Mean fluoroscopy time and dose rose from 6.9 seconds and 0.9 mGy in underweight patients to 10.0 seconds and 6.7 mGy in those with severe obesity (BMI above 40).
- After adjusting for BMI, race did not affect fluoroscopy time or dose.
- Men had higher exposure for cervical interlaminar and lumbar transforaminal procedures.
- A previous study found that requiring two imaging views increased radiation dose by 133%.
Why this matters
Patients with obesity, and the staff who treat them, receive more radiation per procedure. Recognizing this helps teams plan imaging carefully and use dose-reduction techniques where they matter most.
Limitations
The abstract provides limited detail on the number of procedures and methods. The analysis is retrospective and from a single practice.
Safety takeaways: how to apply it
For pain physicians and procedure teams
- Expect higher radiation in patients with obesity, and use collimation, pulsed fluoroscopy and careful positioning to reduce dose.
- Take only the views needed to confirm safe needle placement.
- Wear full protective equipment, including eyewear.
For hospitals, clinics and safety leaders
- Monitor dose by procedure type and patient size to identify opportunities for reduction.
For patients and families
- Ask how the team adjusts imaging to keep your radiation dose as low as possible.
Reference
- Manchikanti L, Kaye AD, Sanapati MR, Pampati V, Shekoohi S, Hirsch JA. Influence of Obesity, Race and Gender on Radiation Exposure for Epidural Procedures. Curr Pain Headache Rep. 2025 Jan 06;29(1):12. doi:10.1007/s11916-024-01327-2. PMID: 39760932. PubMed: https://pubmed.ncbi.nlm.nih.gov/39760932/
This article is educational information, not legal or medical advice.