Fibrin Glue Sealed Accidental Dural Punctures During Stimulator Lead Placement
By Ivan Urits, MD – Board Certified in Anesthesiology and Pain Medicine
Published March 17, 2026 | Category: Pain Medicine
When spinal cord stimulator (SCS) leads are placed, the needle sometimes goes slightly too far and punctures the dura, the membrane holding the spinal fluid. Leaking fluid can cause a severe positional headache, fluid collections under the skin, wound problems and even meningitis. A 2025 report in Current Pain and Headache Reports described a simple fix done during the same procedure.
This summary is based on the published abstract. Read the abstract on PubMed
What the authors did
The authors reviewed records and imaging for all patients who had SCS implants from January 2020 to April 2024. When an accidental dural puncture occurred, they injected fibrin glue, a biological sealant, through the introducer needle into the epidural space directly over the hole. They then looked for signs of spinal fluid leaks, including fluid collections, pseudomeningocele, post-dural puncture headache, wound infection and meningitis.
What they found
- 107 patients had 194 lead insertions.
- 4 patients (3.7%) had an accidental dural puncture with spinal fluid leak during surgery.
- Each was treated with fibrin glue over the dural hole, and the authors report the technique was highly effective in sealing the leak and preventing spinal fluid leakage.
Why this matters
An unrecognized or untreated spinal fluid leak can turn a routine implant into weeks of disabling headaches, extra procedures or a wound infection. Having a prepared, immediate response means the team can manage the problem on the spot rather than waiting for symptoms.
Limitations
This was a small retrospective series with only four treated cases and no comparison group. Larger studies are needed to confirm how well fibrin glue works compared with other approaches, such as blood patches or conservative care.
Safety takeaways: how to apply it
For pain physicians and procedure teams
- Have a plan for accidental dural puncture before every lead placement, including which sealant or patch technique you will use.
- Document any dural puncture and the steps taken, and tell the patient.
- Monitor closely for headache, fluid collection and signs of infection after a dural puncture.
For hospitals, clinics and safety leaders
- Make sure needed supplies are available in rooms where stimulators are implanted.
For patients and families
- Report a headache that worsens when sitting or standing, clear drainage from the incision, fever or a stiff neck after your implant.
Reference
- Gazzeri R, Galarza M, Occhigrossi F, Viswanath O, Varrassi G, Leoni MLG. Prophylactic Fibrin Glue Application for Immediate Management of Dural Puncture during Spinal Cord Stimulation Lead Placement: a Simple and Effective Technique. Curr Pain Headache Rep. 2025 Mar 25;29(1):70. doi:10.1007/s11916-025-01381-4. PMID: 40131573. PubMed: https://pubmed.ncbi.nlm.nih.gov/40131573/
This article is educational information, not legal or medical advice.