Small Doses of Contrast Dye During Epidural Injections Did Not Cause Thyroid Problems

Small Doses of Contrast Dye During Epidural Injections Did Not Cause Thyroid Problems

By Ivan Urits, MD – Board Certified in Anesthesiology and Pain Medicine

Published June 10, 2025 | Category: Pain Medicine

Iodinated contrast dye is used during most image-guided epidural steroid injections (ESIs) to confirm needle position. Contrast contains iodine, and large doses, such as those used in CT scans, can sometimes affect thyroid function. As ESIs become more common, a 2024 study in Cureus asked whether the small amounts used in these injections affect thyroid tests.

This summary is based on the published abstract. Read the abstract on PubMed

What the authors did

At a university hospital pain center, the team enrolled 124 adults aged 18 to 65 who received ESIs between June 2022 and February 2023. Thyroid hormone levels (free T3, free T4 and TSH) were measured before the procedure and 3 weeks afterward.

What they found

  • The average amount of contrast used was 1.34 mL.
  • Only free T4 rose significantly after the procedure.
  • No patient developed a thyroid disorder.

Why this matters

For most patients, the small dose of contrast used in ESIs appears unlikely to cause thyroid problems. But the measurable change in T4 is a reminder that contrast is a drug, and patients with thyroid disease, those who receive frequent injections, or those who have other contrast exposures may warrant attention.

Limitations

The study was small, from one center, excluded patients over 65 and measured thyroid function only once, at 3 weeks. Patients with existing thyroid disease were not specifically studied.

Safety takeaways: how to apply it

For pain physicians and procedure teams

  • Use the smallest amount of contrast needed to confirm needle placement.
  • Ask about thyroid disease, contrast allergy and recent contrast exposure before procedures.
  • Consider coordinating with the patient's physician for those with unstable thyroid disease or frequent contrast exposure.

For hospitals, clinics and safety leaders

  • Record the contrast type and volume used in every procedure note.

For patients and families

  • Tell your team if you have thyroid disease or have recently had a CT scan or other test with contrast dye.

Reference

  1. Isik R, Kokar S, Olgun Y, Sencan S, Gunduz H. The Impact of Iodinated Contrast Media Used in Epidural Steroid Injections on Thyroid Function Tests. Cureus. 2024 Oct;16(10):e70888. doi:10.7759/cureus.70888. PMID: 39497879. PubMed: https://pubmed.ncbi.nlm.nih.gov/39497879/