Cement Leakage in Vertebroplasty and Kyphoplasty: Common, but Usually Without Harm

Cement Leakage in Vertebroplasty and Kyphoplasty: Common, but Usually Without Harm

By Ivan Urits, MD – Board Certified in Anesthesiology and Pain Medicine

Published January 14, 2025 | Category: Pain Medicine

Vertebroplasty (PVP) and kyphoplasty (PKP) treat painful osteoporotic compression fractures by injecting bone cement into the broken vertebra. Kyphoplasty first creates a cavity with a balloon, which is thought to reduce cement leaking outside the bone. A systematic review published in the European Spine Journal asked whether vertebroplasty really carries a higher risk of leaks and, more importantly, of leak-related harm.

This summary is based on the published abstract. Read the abstract on PubMed

What the authors did

The authors searched the literature and found six studies that directly compared cement leakage and complications between the two procedures: three randomized trials and three retrospective comparisons. They focused on serious leak-related problems: nerve compression, cement traveling to the lungs (pulmonary embolism) and the need for emergency decompression surgery.

What they found

  • Among 532 vertebroplasties and 493 kyphoplasties, leaks occurred in 39.3% of vertebroplasties and 28.9% of kyphoplasties, a significant difference.
  • None of the leaks in these studies caused nerve compression, pulmonary embolism or emergency surgery.
  • The data were too varied to combine in a meta-analysis.

The authors conclude that vertebroplasty produces more leaks, but the difference does not appear to be clinically significant in these studies.

Why this matters

Cement leakage is common in both procedures, and most leaks are small and silent. Still, rare leaks into veins or the spinal canal can be serious, which is why technique and imaging matter. This review helps put the risk in perspective while reinforcing the need for careful monitoring.

Limitations

Only six studies qualified, and they varied in design and how leaks were detected. Rare serious complications may not appear in studies of this size.

Safety takeaways: how to apply it

For pain physicians and procedure teams

  • Inject cement slowly under continuous high-quality imaging, and stop if cement moves toward veins, the front of the vertebra or the spinal canal.
  • Use appropriately thick cement and plan needle position carefully.
  • Know the signs of cement embolism, such as sudden shortness of breath, chest pain or low oxygen.

For hospitals, clinics and safety leaders

  • Track leakage and leak-related complications as quality measures.

For patients and families

  • Report new chest pain, shortness of breath, leg pain or weakness after the procedure right away.

Reference

  1. Rose LD, Bateman G, Ahmed A. Clinical significance of cement leakage in kyphoplasty and vertebroplasty: a systematic review. Eur Spine J. 2024 Apr;33(4):1484-1489. doi:10.1007/s00586-023-08026-3. PMID: 37999769. PubMed: https://pubmed.ncbi.nlm.nih.gov/37999769/